High performance power line filter
|
|
|
Features and benefits
-
High performance power line filter serie is designed to meet highest filter attenuation requirements over a wide range starting from a few kilohertz up to 5GHz required for TEMPEST protection.
-
Additional high surge voltage protection supports NEMP requirements.
-
Choosing the High performance product line brings you the rapid availability of a power line filter associated with the neccessary safety acceptances.
-
Standard filters are a practical solution helping you to pass EMI system approval in an short time.
-
Exceptional conducted attenuation performance, based on three-stage design and chokes with high saturation resistance and excellent thermal behaviour.
-
Integrated gas discharge tubes and suppressors.
-
IEC inlet version for 6 and 10A types.
-
Custom-specific versions on request.
|

-
Rated currents from 6 to 20A
-
IEC inlet for 6 and 10A versions
-
TEMPEST/NEMP
-
Up to 3GHz attenuation
-
High surge voltage protection
|
|
Mounting
These protections are designed for mounting on the penetration panel or directy on the non-painted wall of the Faraday cage.
|
|
|
Typical applications
- Facility management
- Information protection
- Telecommunication
- Data processing
- Medical equipment
- Electrical and electronic equipment
|
|
|
Technical specifications
|
Maximum continuous operating voltage
|
: 250 VAC, 50/60Hz |
| Operating frequency |
: dc to 400Hz (6 and 10A types) |
| : dc to 60Hz (20A types) |
| Rated currents |
: 1 to 20A @ 40ºC max. |
| High potential test voltage |
: P -> E 590VAC for 2 sec |
| |
: P -> N 590VAC for 2 sec |
| Temperature range (operation and storage) |
:-25ºC to +85ºC (25/85/21) |
| Flammability corresponding to |
: UL 94V-2 or better |
| Design corresponding to |
: UL 1283, CSA 22.2 No. 8 1986, IED/EN 60939 |
| MTBF @ 40ºC/230V (Mil-HB-217F) |
:450,000 hours |
|
|
|
Models and ordering data
|
Reference
|
rated Current
|
Input and output
|
Resistance R
|
Leakage current @230VAC/50Hz
|
Approximative weight
|
|
(A)
|
*Type
|
(MΩ)
|
(mA)
|
(Kg)
|
|
HP - 4006
|
6 (6.9)
|
1
|
0.33
|
0,44
|
2
|
|
HP - 4010
|
10 (11.6)
|
1
|
0.33
|
0,44
|
2.3
|
|
HP - 4020
|
20 (23)
|
2
|
0.33
|
2,6
|
3.5
|
For the explanation of the reference see chapter "how to order" below
*See "Mechanical data" pictures below
|
|
|
Attenuation characteristics
Measurement method: Per CISPR 17 / 50Ω/50Ω sym;
| 6A Types |
10 and 20A types |
 |
 |
|
|
|
Dimensions in mm
|
Reference
|
A
|
B
|
C
|
D
|
E
|
F
|
G
|
H
|
I
|
J
|
K
|
L
|
M
|
N
|
|
HP - 4006
|
200
|
80
|
50
|
15
|
85
|
50
|
40
|
30
|
20
|
40
|
20
|
40
|
M4 x 6
|
6.3 x 0.8
|
|
HP - 4010
|
250
|
80
|
50
|
25
|
100
|
50
|
40
|
30
|
20
|
40
|
20
|
40
|
M4 x 6
|
6.3 x 0.8
|
|
HP - 4020
|
275
|
110
|
50
|
25
|
112.5
|
94
|
60
|
15
|
25
|
55
|
34
|
94
|
M4 x 6
|
M4
|
* For the explanation of the reference see chapter " how to order " below
|
|
Mechanical data
(Type 1) 6 and 10A types
|
 |
(Type 2) 20A types |
 |
|
|
How to order
The picture below explaines how to generate a High performance part number. - Serie (HP = High performance); - the amount of phases; - the current (A); - and then the amount of volts (250/400).

|